POWER SAN TRUE ON LINE UPS 6 & 10 kva

DOUBLE CONVERSION, PURE SINE WAVE

CHARACTERISTICS

  • Double conversion, Multi-Frequency I/O
  • DSP Control Technology, Digital Display
  • Advanced input Power Factor Correction (PFC)
  • Wide input Voltage range, By-pass battery
  • Output Power Factor 0.9
  • Cold Start (DC power ON)
  • Auto adjustable frequency
  • High Efficient ECO Mode for saving energy
  • Output Voltage selectable via LCD panel
  • Low battery voltage selectable via LCD
  • Self-diagnosis at startup
  • Short circuit and overload protections
  • Auto charging batteries at UPS off mode
  • Fan speed automatically changes as “LOAD” varies
  • Easy monitoring via SNMP (optional)
  • Emergency Power Off (EPO)
  • External battery bank connector
  • By-pass output programmable via LCD
  • RS232 and USB ports for power management software
  • Advance Battery Management(ABM) 6/10K only
  • Isolation Transformer, Dual 120/220V (6&10K)
  • Redundancy in Parallel N + X (Max. parallel 6 units) 6 & 10K only

Back Panel of 6 & 10 KVA

 

1. AC input
2. Modem/Tel/Fax
3. External Battery Bank connect
4. Output Sockets (Load)
5. Cooling Fan

 

6. AC input
7. Modem/Tel/Fax
8. External Battery Bank connect
9. Output Sockets (Load)
10. Cooling Fan

KENJITSU UPS POWER SAN SERIES SPECIFICATION

MODELO 6KVA10KVA
Capacity6KVA / 5400W10KVA / 9000W
INPUT
Input Voltage220V (L1 - L2, G)
Voltage Range(115 - 295) ±5Vac (60% load); (155 - 295) ±5Vac (100% load)
Frequency(50/60) Hz auto-adaptive ; (40 - 70Hz, ±0.5%)
Input Current (Max.)24A 45A
Power Factor>0.98
Total Harmonic Distortion (THDI)<5%
Bypass voltage range(180 - 255) ±5Vac 100% load
OUTPUT
Voltage range208/220/230/240) Vac Setting available via LCD (100/110/115/120) Vac Setting available via LCD
Power Factor0.9
Total Harmonic Distortion (THDv)Full linear load <2% Full! Non-linear load 150%: 100ms;
Voltage accuracy±1%
Load crest3:1
Transfer time from AC mode to BAT mode0ms
Transfer time from BAT mode to AC mode0ms
EFFICIENCY
Line mode92% (Full! load & 100% charged batteries)
BAT mode91% (Full! load & 100% charged batteries)
ECO mode98% (Full! load & 100% charged batteries)
BATTERY
Battery typeSealed lead add maintenance free battery (VLRA)
Quantity x Capacity16 x (12/9AH)
DC voltage192V
Backup time18min 6s (50% load) / 09min 0s (50% load)
Charger current1A / 3A / 5A / 8A (selectable)
Battery bank external connectorAnderson gray connector type (cover for connector)
SYSTEM CONTROL & COMMUNICATION
Communication portRS232; USB, SNMP card (optional)
Software functionGraphics analyze; Switch on/off UPS system; Monitor UPS working status; History record and event log
ProtectionOver-temp protect ion; Fan testing protection; Output short circuit protection
TopologyLast generation IGBT, inverter & rectifier
AltitudeNormal up to 1000m, 1% derating in every 100m
ENVIRONMENT
Operating temperature0°C ~ 40°C
Recommended temperature15°C ~ 25°C
Storage temperature15°C ~ 50°C
CoolingFan speed auto control when load varies
Humidity20 ~ 90% (non condensing)
Noise level<55dB
PHYSICAL
Dimension WxDxH(710 x 735 x 262) mm
Weight with internal batteries115.2Kg / 116.2Kg
REQUEST A QUOTE